Unit #1 and #2 are done, grease was applied to scroll pump for unit #1 and #2, and to all electrical motors.
Compression test results:
- Unit #1 pressure 125 psi
- Unit #2 pressure 120 psi
- Unit #3 pressure 120 psi
- Unit #4 pressure 125 psi
- Unit #5 pressure 125 psi
Scroll pumps #3, #4 and #5 need to be greased.
Unit #2 needs a new one-way valve.
Unit #5 needs a new relief valve, but all other relief valves are OK.
Done under WP 6541.