WP6540 Reduce cronjobs on HEPI Pump Controllers
Dave:
Completed EY config, applied config to EX and L0.
WP6539 Relocate HWS frame grabber card from EX to MSR1
Carlos, Nutsinee, Dave:
Card was relocated, but we appear to have driver issues on the spare HWS machine. Carlos is working with TCS to install this machine from scratch and put the configuration into puppet.
WP6543 Upgrade cdslogin to Debian8
Carlos, Jonathan, Jim, Dave
cdslogin was upgraded from U12 to Deb8.
WP6544 New code h1calcs and h1omc
Daniel, Kiwamu, Jim, Dave:
New code was installed on h1omc and h1calcs. A new dolphin sender was installed on omc, with corresponding receiver on calcs. Two 4k DQ channels were added to the DAQ, along with a few dozen slow channels.
WP6546 New PCAL guardian node
TJ, Rick, Sudarshan
A new temporary guardian node named HIGH_FREQ_LINES was added
WP6519 Put seismon channels into DAQ.
Not done, defer to later time