Nutsinee, Kiwamu (on email and phone)
INITIAL ALIGNMENT
MICH_DARK_LOCKED had a bit of an issue today. It wouldn't go dark no matter how good the alignment seemed. Kiwamu suggested I added 5 counts offset on MICH1. But I was coming back from SRC_ALIGN so I had 10W while attempted to lock MICH for the last time. It worked. Not sure what fixed it though. That 5 counts offset has been removed as soon as I got pass MICH.
Spent quite some time on SRC_ALIGN. It seems like every time ASC tried to engage it kicked SRM too hard and tripped the WD. Beam looked round and error signals looked fine (fluctuating around 0). Just when I decided to call Kiwamu ASC was able to engage.
LOCK ACQUISITION
OMC was a little shy. Needed to request READY_FOR_HANDOFF twice.
SDFs
Accepted a couple of SDFs (LSC-ASAIR and SUS_OMC) so I could flip the intent bit. Let us (ops) know if we should revert them back next time we loses lock.These are probably the left overs from PRMI work. See the attachment.
Lockloss 04:23
Stepped out to make coffee. PI rung up when I came back. Couldn't damp it in time.
05:05 UTC Back to Observe