chandra.romel@LIGO.ORG - posted 11:27, Thursday 30 March 2017 - last comment - 17:15, Monday 03 April 2017(35222)
HAM 6 pressure spike

HAM 6 pressure spiked at around 23:00 UTC time on 3/29.

 

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 12:25, Thursday 30 March 2017 (35224)

This looks like about the same time that we were testing the fast shutter.  Do we get this kind of pressure spike during a normal lockloss?

chandra.romel@LIGO.ORG - 17:15, Monday 03 April 2017 (35300)

We don't typically see spikes like this. We have been monitoring pressures across the site, including HAM 6, in 48 hr increments for a few months now to detect peculiar spikes like this.

Note that we saw several spikes like this before the failure of the OMC which Daniel attributed to "liquid glass":  https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=28840