Displaying report 1-1 of 1.
Reports until 12:10, Friday 31 March 2017
LHO VE
logbook/robot/script0.cds.ligo-wa.caltech.edu@LIGO.ORG - posted 12:10, Friday 31 March 2017 - last comment - 13:32, Friday 31 March 2017(35248)
CP3, CP4 Autofill 2017_03_31
Starting CP3 fill. LLCV enabled. LLCV set to manual control. LLCV set to 50% open. Fill completed in 571 seconds. TC B did not register fill. LLCV set back to 17.0% open.
Starting CP4 fill. LLCV enabled. LLCV set to manual control. LLCV set to 70% open. Fill completed in 3188 seconds. TC A did not register fill. LLCV set back to 33.0% open.
Images attached to this report
Comments related to this report
chandra.romel@LIGO.ORG - 13:32, Friday 31 March 2017 (35249)

Raised CP3 to 18% open (was 17%) and CP4 to 36% open (was 33%).

FYI we are losing our striptool scans for these fills. Robo-log will still be generated. Also the text alert will be generated at noon (rather than 10:45) reminding us to check that fill completed.

Displaying report 1-1 of 1.