Reports until 13:56, Friday 31 March 2017
H1 SEI
hugh.radkins@LIGO.ORG - posted 13:56, Friday 31 March 2017 - last comment - 11:26, Tuesday 04 April 2017(35250)
BRSY Remote Desktop session exited at 2050--2051utc

As Krishna noted in aLog 35160, this machine does not have a lot of extra juice to run this.  I should have closed out before but was watching the diagnostics.  Jim turned off the sensor correction so in case the session closing glitched things, it would not glith the ISI/IFO.  It did not and SC has been turned back on.

Comments related to this report
krishna.venkateswara@LIGO.ORG - 11:26, Tuesday 04 April 2017 (35314)DetChar, SEI

I've attached about 10 hours of BRS-Y driftmon data around the time of this crash. It looks like this crash was caused by trying to use BRS-Y in a bad range. Even if the data looks temporarily smooth, BRS-Y should not be used if driftmon is below -15k counts.

The close time association with closing of the remote desktop terminal was likely just a coincidence. It is still advised to not login to the machine remotely when BRS-Y is being used for feedforward, unless really necessary.

Images attached to this comment