J. Kissel WP #6557 In order facilitate regular, bi-weekly, CAL measurements, I've added a new state to the ISC_LOCK guardian code called "NLN_CAL_MEAS." So far, the state only turns OFF all calibration lines, as is needed for the frequency dependent sweeps. Upon request to return to NOMINAL_LOW_NOISE, it turns the calibration lines back on, and clears the history in the calculations for front-end calculated time-dependent correction factors (which, sadly, will take several minutes given the impulse responses of some low pass filters in the calculation). I'll install and test the state tomorrow (4/4) after maintenance is complete. Thus far, I've only - checked for a clean svn status before I started, - written in the change to the ISC_LOCK guardian, - saved it, - checked if the graph was OK with the new edges, - commented out all new code - committed ISC_LOCK to the svn so if the code, for whatever reason, gets loaded before tomorrow, there will be no change applied. I attach the test of the new edges and the representative graph to show how this state fits in the bigger picture.