Fil, Richard, Nutsinee
Quick conclusion: The camera and the pick-off beam splitter is in place, but not aligned.
Details: First I swapped the camera fiber cable back so h1hwsmsr can stream images from HWSX camera while I install the BS.
While looking at the stream images, I positioned the BS in such a way that doesn't cause a significant change to the stream images (I didn't take the HW plate off).
Then I installed the camera (screwed on to the table). Because the gate valves were close for the Pcal camera installation, I didn't have the green light to do the alignment.
Richard got the network streaming to work. Now we can look at what the GigE sees though CDS >> Digital Video Cameras. There's nothing there.
The alignment will have to wait until a next opportunity now that green and the IR are back (LVEA is still laser safe).
The camera is left powered on, connected to the Ethernet cable, and CCD cap off.
I re-ran the python script, retook the reference centroids. From 1175379652 GPS time the data written to /data/H1/ITMX_HWS comes from HWSX camera.
Specification
Camera: BASLER scA1400-17gc
Beam Splitter: Thorlabs BSN17 2"diameter 90:10 UVFS BS Plate, 700-110nm t=8mm