PI mode 19 started to ring up a bit to cause the SUS_PI node to change some of the PLL filters causing an SDF diff. Mode 19 is not one of the modes that we regularly damp while at 30W, but it may have been excited from the wind. I went to clear the SDF diff but just trying to click the unmonitor button would not work, there was an exclamation point next to the "MON" but I'm not quite sure if that was suppose pop up a screen for me that didn't work remotely, or if it was something else. I managed to select the unmonitor all, with only that channel having an FM3 diff, and getting it to accept it that way. I'm worried that this may have accepted the entire filter bank, and there was another screen that I couldn't see that would allow me to choose what parts on that filter bank to monitor.
We are back to Observing and there is a screenshot below of the SDF diff.
I brought this back to how it was before I unmonitored this entire bank, but I unmonitored the FMs since the PI Guardian can change them. I was correct that I was suppose to get another screen for the filter bank when clicking the !MON button, but I could not get this remotely.