Suspension watchdog threshold values
I have been investigating the seismic system watchdogs. We want to know if the watchdogs threshold amount of motion to shut down the controls of the system can be relaxed. As a first step in doing this I found the threshold values for each of the suspension watchdogs. The channel and the corresponding threshold are shown below.
H1:SUS-ITMX_M0_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-ITMX_R0_WD_OSEMAC_RMS_MAX 10000.0
H1:SUS-ITMX_L2_WD_OSEMAC_RMS_MAX 8000.0
H1:SUS-ITMX_L1_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-TMSY_M1_WD_OSEMAC_RMS_MAX 8000.0
H1:SUS-SRM_M1_WD_OSEMAC_RMS_MAX 15000.0
H1:SUS-SRM_M3_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-SRM_M2_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-SR3_M1_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-SR3_M3_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-SR3_M2_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-PR2_M1_WD_OSEMAC_RMS_MAX 8000.0
H1:SUS-PR2_M3_WD_OSEMAC_RMS_MAX 8000.0
H1:SUS-PR2_M2_WD_OSEMAC_RMS_MAX 8000.0
H1:SUS-ETMX_M0_WD_OSEMAC_RMS_MAX 25000.0
H1:SUS-ETMX_R0_WD_OSEMAC_RMS_MAX 25000.0
H1:SUS-ETMX_L2_WD_OSEMAC_RMS_MAX 25000.0
H1:SUS-ETMX_L1_WD_OSEMAC_RMS_MAX 25000.0
H1:SUS-OMC_M1_WD_OSEMAC_RMS_MAX 12000.0
H1:SUS-IM2_M1_WD_OSEMAC_RMS_MAX 8000.0
H1:SUS-OM3_M1_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-ITMY_M0_WD_OSEMAC_RMS_MAX 13000.0
H1:SUS-ITMY_R0_WD_OSEMAC_RMS_MAX 13000.0
H1:SUS-ITMY_L2_WD_OSEMAC_RMS_MAX 13000.0
H1:SUS-ITMY_L1_WD_OSEMAC_RMS_MAX 13000.0
H1:SUS-BS_M1_WD_OSEMAC_RMS_MAX 8000.0
H1:SUS-BS_M2_WD_OSEMAC_RMS_MAX 8000.0
H1:SUS-IM1_M1_WD_OSEMAC_RMS_MAX 8000.0
H1:SUS-MC3_M1_WD_OSEMAC_RMS_MAX 25000.0
H1:SUS-MC3_M3_WD_OSEMAC_RMS_MAX 15000.0
H1:SUS-MC3_M2_WD_OSEMAC_RMS_MAX 15000.0
H1:SUS-RM1_M1_WD_OSEMAC_RMS_MAX 8000.0
H1:SUS-IM4_M1_WD_OSEMAC_RMS_MAX 8000.0
H1:SUS-OM1_M1_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-MC1_M1_WD_OSEMAC_RMS_MAX 25000.0
H1:SUS-MC1_M3_WD_OSEMAC_RMS_MAX 15000.0
H1:SUS-MC1_M2_WD_OSEMAC_RMS_MAX 15000.0
H1:SUS-ETMY_M0_WD_OSEMAC_RMS_MAX 16000.0
H1:SUS-ETMY_R0_WD_OSEMAC_RMS_MAX 8000.0
H1:SUS-ETMY_L2_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-ETMY_L1_WD_OSEMAC_RMS_MAX 8000.0
H1:SUS-TMSX_M1_WD_OSEMAC_RMS_MAX 8000.0
H1:SUS-SR2_M1_WD_OSEMAC_RMS_MAX 11000.0
H1:SUS-SR2_M3_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-SR2_M2_WD_OSEMAC_RMS_MAX 8000.0
H1:SUS-OM2_M1_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-PR3_M1_WD_OSEMAC_RMS_MAX 15000.0
H1:SUS-PR3_M3_WD_OSEMAC_RMS_MAX 15000.0
H1:SUS-PR3_M2_WD_OSEMAC_RMS_MAX 15000.0
H1:SUS-MC2_M1_WD_OSEMAC_RMS_MAX 18000.0
H1:SUS-MC2_M3_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-MC2_M2_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-RM2_M1_WD_OSEMAC_RMS_MAX 25000.0
H1:SUS-PRM_M1_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-PRM_M3_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-PRM_M2_WD_OSEMAC_RMS_MAX 80000.0
H1:SUS-IM3_M1_WD_OSEMAC_RMS_MAX 8000.0
Comments related to this report
iain.dorrington@LIGO.ORG - 14:37, Friday 07 April 2017 (35396)
A link to the corresponding report for Livingston https://alog.ligo-la.caltech.edu/aLOG/index.php?callRep=32886