With J. Kissel, A. Viets, D. Barker; Re: WP 6567 and 6572.
The work listed on the above work permits is now done.
i. DMT yum updates and reboots are done. DMT is now running ROOT6 and gstlal-calibration-1.1.5.
ii. Channels were added to the framebroadcaster:
H1:CAL-CS_TDEP_ESD_LINE1_REF_A_TST_NOLOCK_REAL H1:CAL-CS_TDEP_ESD_LINE1_REF_A_TST_NOLOCK_IMAG H1:CAL-CS_TDEP_PCALY_LINE4_REF_C_NOCAVPOLE_REAL H1:CAL-CS_TDEP_PCALY_LINE4_REF_C_NOCAVPOLE_IMAG H1:CAL-CS_TDEP_PCALY_LINE4_REF_D_REAL H1:CAL-CS_TDEP_PCALY_LINE4_REF_D_IMAG H1:CAL-CS_TDEP_PCALY_LINE4_REF_A_TST_REAL H1:CAL-CS_TDEP_PCALY_LINE4_REF_A_TST_IMAG H1:CAL-CS_TDEP_PCALY_LINE4_REF_A_USUM_REAL H1:CAL-CS_TDEP_PCALY_LINE4_REF_A_USUM_IMAG
iii. DMT calibration hoft and DCS aggregated hoft updated to now output these new channels:
H1:GDS-CALIB_F_S
H1:GDS-CALIB_F_S_NOGATE
H1:GDS-CALIB_SRC_Q_INVERSE
H1:GDS-CALIB_SRC_Q_INVERSE_NOGATE
starting from 1175978240 (Apr 11 2017 20:37:04 UTC).
That completes DMT/calibration updates and SRC detuning time dependent tracking in work permits 6567 and 6572 respectively.