There were number of high frequency calibration lines injected using the automated Guardian scripts. These lines are injected using the Pcal at ENDX (ENDY is used for calibration purpose). The GPS time at which these lines were running are listed below:
Frequency | Starttime | Endtime |
2001.3 | 1174765755 | 1174843009 |
2501.3 | 1174843010 | 1175048873 |
3001.3 | 1175048874 | 1175185602 |
3501.3 | 1175185604 | 1175280996 |
4001.3 | 1175280998 | 1175367396 |
4501.3 | 1175367398 | 1175532906 |
5001.3 | 1175532908 |
Rick, Sudarshan
Th high frequency line was moved to 5501.3 Hz. The guardian script was designed to go upto 5001.3 Hz so Rick moved the frequency to 5501.3 Hz manually during the maintenance period. We will move this line to 6001.3 Hz when we have enough data and the ifo goes out of lock next time.
Updated list of lines with their start and endtime.