A2L measurement showed elevated in Yaw, so ran A2L.
4.7kHz was damped at the beginning of the lock last night with 0deg (MODE10 outmon went down to +/-2000counts on strip tool). But saw that the resonance was rung up again. So, I tried +30deg & this quickly rung up the resonance. I then added -60deg (for net -30deg) & this took damped out the resonance within minutes (& took the MODE10 outmon to +/-10 counts).
Summary of 10min out of Observing: