L1 Down, Ran A2L & Damped 4.7kHz

A2L measurement showed elevated in Yaw, so ran A2L.

4.7kHz was damped at the beginning of the lock last night with 0deg (MODE10 outmon went down to +/-2000counts on strip tool).  But saw that the resonance was rung up again.  So, I tried +30deg & this quickly rung up the resonance.  I then added -60deg (for net -30deg) & this took damped out the resonance within minutes (& took the MODE10 outmon to +/-10 counts).

Summary of 10min out of Observing: