ASC sensing matrix measurement

[Vaishali, Jenne]

We used the last few minutes of commissioning time today to measure the ASC sensing matrix.  This is the first time that we have made this measurement since POPX was installed.  Per JeffK's suggestion, we turned off the 7.9Hz calibration line to avoid confusion with our 8.125Hz measurement frequency (we used his new guardian state that actually turns off all the Pcal lines, then turns them back on before we go to NLN).  

Vaishali is looking at this data to compare with previous measurements, and her Finesse model.

Recall that in the table below, elements that are grayed out have lower coherence.


Sensing Matrix, [W/rad]

dof:
CHARD

INP1

PRC1

PRC2

DHARD

SRC1

SRC2

MICH

AS_A_DC_PIT

2.65e+02
154

1.5e-03
266

5.51e+01
-179

8.72e+02
319

6.83e+03
160

6.46e+01
178

3.23e+02
179

2.96e+02
118

AS_A_RF36_I_PIT

1.61e+04
-22

1.55e-01
247

6.02e+03
177

1.06e+05
321

1.7e+03
-84

5.27e+02
0

1.60e+04
0.4

1.56e+03
-96

AS_A_RF36_Q_PIT

4.55e+03
-15

5.2e-02
43

1.88e+03
-158

2.10e+04
178

1.70e+05
161

5.63e+02
185

9.97e+03
358

1.58e+05
122.5

AS_A_RF45_I_PIT

3.5e+02
107

6.7e-03
265

4.19e+02
175

7.54e+03
320

7.76e+04
-17

5.73e+01
181

4.6e+01
203

1.78e+03
-58

AS_A_RF45_Q_PIT

1.34e+04
-28

6.09e-02
73

3.81e+03
-3

6.40e+04
136

1.58e+06
161.9

4.28e+02
357

6.55e+03
177

1.25e+04
-52

AS_B_DC_PIT

3.95e+02
-21

5.69e-03
258

7.8e-01
65

4.24e+01
128

7.62e+02
3

1.02e+02
358

1.74e+02
177

2.72e+02
-60

AS_B_RF36_I_PIT

1.32e+04
157

1.29e-01
68

5.44e+03
0

6.90e+04
138

8.00e+04
161

4.18e+03
179.5

1.14e+04
357

7.70e+04
126

AS_B_RF36_Q_PIT

1.19e+04
-23

2.26e-01
263

5.16e+03
-176

8.15e+04
317

1.33e+05
158

3.34e+02
184

7.04e+02
173

1.43e+05
114

AS_B_RF45_I_PIT

1.21e+03
-25

3.05e-02
80

8.27e+02
-1

1.33e+04
137

1.02e+05
162

3.74e+01
356

4.14e+01
4

1.28e+03
-50

AS_B_RF45_Q_PIT

4.50e+03
130

1.63e-01
259

2.49e+03
176

4.08e+04
315

1.35e+06
-16

8.21e+02
2

1.90e+03
188

1.14e+04
129

AS_C_PIT

1.90e-03
-19

6.30e-08
260

2.63e-04
177

3.88e-03
316

3.05e-02
167

6.92e-04
0

3.18e-03
179

1.31e-03
-56

REFL_A_DC_PIT

1.5e+02
-10

2.49e-02
82

3.10e+00
-156

5.28e+01
139

4.6e+01
-2

1.3e-01
232

5.7e+00
352

9.5e+00
117

REFL_A_RF9_I_PIT

2.98e+05
-18.2

5.72e+01
81

1.6e+03
-170

9.33e+04
152

2.0e+04
-30

6.0e+01
206

1.3e+03
188

2.4e+03
-112

REFL_A_RF9_Q_PIT

1.30e+05
-15

8.46e+00
82

5.03e+03
-2

1.80e+04
151

9.2e+03
-1

3.3e+01
201

4.4e+02
351

1.7e+03
127

REFL_A_RF45_I_PIT

2.81e+05
-18

7.26e+01
81

1.28e+04
-176

5.49e+04
171

1.6e+04
-26

1.9e+01
19

1.2e+03
181

1.06e+04
126

REFL_A_RF45_Q_PIT

9.28e+04
-13

2.61e+01
82

4.22e+03
-179

2.00e+03
61

8.2e+03
1

3.79e+01
355

2.3e+02
346

2.3e+03
-98

REFL_B_DC_PIT

1.06e+02
156

1.29e-02
259

4.90e+00
-175

3.32e+01
319

2.8e+01
150

5.97e-02
348

1.8e+00
336

7.8e+00
110

REFL_B_RF9_I_PIT

2.61e+05
-15

6.47e+01
261

4.30e+04
-1

1.80e+05
147

2.83e+04
171

1.26e+02
341

4.8e+02
224

2.1e+03
-156

REFL_B_RF9_Q_PIT

4.05e+04
-14

2.87e+01
261

1.45e+04
-1

5.14e+04
146

9.65e+03
170

9.13e+01
352

2.2e+02
210

9.38e+02
-150

REFL_B_RF45_I_PIT

2.78e+05
-16

7.77e+01
261.4

4.00e+04
0

1.01e+05
324

3.12e+04
174

1.14e+02
2

4.8e+02
317

1.56e+04
-135

REFL_B_RF45_Q_PIT

1.19e+05
-15

3.63e+01
261

1.97e+04
2

8.93e+04
334

9.03e+03
164

4.54e+01
328

3.2e+02
193

6.19e+03
44

POP_X_RF_I_PIT

1.03e+05
166

3.34e+00
260

4.57e+04
179.6

7.56e+05
319.0

9.91e+03
84

5.73e+02
184

2.8e+02
359

6.12e+04
107

POP_X_RF_Q_PIT

4.73e+03
162

6.0e-02
259

9.69e+02
-157

5.35e+03
285

2.14e+04
165

1.63e+02
171

2.4e+02
21

1.86e+04
126

POP_A_PIT

4.76e+00
-18

1.65e-05
257

3.47e-01
178

2.91e-01
137

5.05e-01
-21

1.18e-03
359

3.8e-03
137

6.50e-02
-43

POP_B_PIT

1.57e+00
163

3.22e-05
260

8.55e-01
178

2.24e-01
319

1.71e-01
-25

2.00e-03
177

2.6e-03
84

4.14e-02
118

X_TR_A_PIT

3.02e+03
162

1.60e-03
275

2.57e+00
-175

6.52e+01
324

2.82e+03
161

1.50e-01
337

8.22e-01
156

2.73e+00
-159

X_TR_B_PIT

3.54e+03
162

1.96e-03
283

3.42e+00
-167

8.17e+01
330

3.17e+03
160

2.84e-01
342

9.88e-01
128

4.85e+00
-168

Y_TR_A_PIT

3.76e+03
161

2.15e-03
261

3.87e+00
158

9.11e+01
305

3.71e+03
-19

6.97e-02
9

8.77e-01
314

1.34e+01
122

Y_TR_B_PIT

1.13e+03
162

9.64e-04
237

1.42e+00
127

3.01e+01
274

1.23e+03
-21

1.85e-01
358

3.4e-01
280

5.29e+00
124
Comments related to this report
vaishali.adya@LIGO.ORG - 11:51, Wednesday 26 April 2017 (35801)

[ Jenne, Vaishali ]

Today we used the commissioning window to re-measure the ASC sensing matrix for Pitch and the results show that the values for the individual DoFs hasn't changed by too much. We will now make radar plot comparisons of the same and compare them to alog 26023 

Sensing Matrix, [W/rad]

dof: CHARD DHARD CSOFT DSOFT MICH SRC1 SRC2 PRC1 PRC2 INP1
AS_A_DC_PIT 2.35e+02 157 6.51e+03 160 1.18e+02 -17 4.28e+02 162 2.64e+02 117 5.85e+01 178 3.27e+02 178 4.86e+01 179 7.88e+02 319 1.5e-03 250
AS_A_RF36_I_PIT 1.33e+04 -23 5.12e+03 -164 1.50e+04 164 6.64e+03 -6 6.02e+03 139 2.14e+02 179 1.70e+04 0.2 6.00e+03 179 1.04e+05 319 1.69e-01 260
AS_A_RF36_Q_PIT 3.66e+03 -23 1.68e+05 162 4.36e+03 156 1.92e+05 -18.7 1.54e+05 122.9 1.05e+02 222 9.14e+03 357 7.24e+02 -123 3.08e+04 160 1.4e-01 90
AS_A_RF45_I_PIT 3.9e+02 151 7.86e+04 -16 3.0e+02 44 1.00e+03 -36 1.39e+03 -61 5.91e+01 182 3.93e+01 196 6.60e+02 177 1.12e+04 319 5.8e-03 263
AS_A_RF45_Q_PIT 1.65e+04 -31 1.46e+06 162.0 7.58e+03 177 8.65e+04 156 1.39e+04 -52 4.10e+02 358 6.08e+03 177 4.10e+03 -3 6.46e+04 136 4.82e-02 79
AS_B_DC_PIT 3.89e+02 -29 7.12e+02 11 1.61e+02 -177 9.41e+01 94 2.47e+02 -62 9.48e+01 358 1.69e+02 178 1.45e+01 -12 2.06e+02 133 4.79e-03 255
AS_B_RF36_I_PIT 1.31e+04 158 7.52e+04 163 1.63e+04 -19 8.75e+04 -16 7.26e+04 130 4.18e+03 179.7 1.20e+04 357 4.71e+03 0 7.65e+04 141 2.42e-01 85
AS_B_RF36_Q_PIT 6.67e+03 -42 1.15e+05 158 7.53e+03 156 1.42e+05 -24 1.27e+05 112 2.45e+02 197 1.06e+03 185 3.76e+03 -171 5.31e+04 315 1.56e-01 262
AS_B_RF45_I_PIT 2.41e+03 -24 1.09e+05 162 5.98e+02 -66 6.28e+03 153 1.73e+03 -59 5.72e+01 358 7.6e+00 54 1.11e+03 0 1.76e+04 139 4.10e-02 79
AS_B_RF45_Q_PIT 6.43e+03 132 1.37e+06 -16 9.32e+03 -8 8.31e+04 -22 1.30e+04 127 6.94e+02 1 1.76e+03 187 2.53e+03 177 3.97e+04 316 1.51e-01 260
AS_C_PIT 1.63e-03 -5 2.57e-02 167 1.10e-03 137 2.36e-03 165 1.19e-03 -58 6.40e-04 0 3.11e-03 179 1.02e-04 174 1.95e-03 313 5.61e-08 261
REFL_A_DC_PIT 6.1e+01 27 1.3e+02 -18 6.5e+01 -39 6.9e+01 30 1.1e+01 -37 2.3e-01 334 6.5e+00 107 3.2e+00 20 4.44e+01 129 1.09e-02 78
REFL_A_RF9_I_PIT 2.70e+05 -16 1.5e+04 -144 1.8e+04 -12 6.2e+03 -117 2.0e+03 -82 6.9e+01 188 1.4e+03 302 5.34e+03 -7 1.45e+05 145 4.34e+01 81
REFL_A_RF9_Q_PIT 1.39e+05 -13 1.7e+04 -15 1.7e+04 -30 1.2e+04 20 1.2e+03 -27 5.36e+01 203 1.0e+03 110 8.62e+03 0 3.75e+04 143 2.83e+00 83
REFL_A_RF45_I_PIT 2.89e+05 -17.3 1.4e+04 -133 5.4e+03 -11 8.2e+03 -83 1.67e+04 122 5.7e+01 201 1.6e+03 302 1.59e+04 -172 5.32e+04 186 7.59e+01 81
REFL_A_RF45_Q_PIT 8.24e+04 -11 1.0e+04 -20 7.5e+03 -32 7.88e+03 35 6.41e+03 -118 5.25e+01 12 4.7e+02 96 5.48e+03 -179 1.16e+04 327 2.77e+01 82
REFL_B_DC_PIT 1.39e+02 156 1.1e+01 155 1.4e+01 -90 1.9e+01 33 3.5e+00 111 1.3e-01 336 2.9e+00 118 2.5e+00 171 4.27e+01 317 2.38e-02 258
REFL_B_RF9_I_PIT 2.30e+05 -15 2.12e+04 166 2.63e+04 -19 5.71e+03 11 5.50e+03 -65 1.29e+02 339 6.9e+02 227 3.94e+04 0 2.10e+05 144 4.86e+01 261
REFL_B_RF9_Q_PIT 3.56e+04 -14 7.4e+03 148 6.34e+03 -20 2.1e+03 25 1.70e+03 -81 6.09e+01 345 4.4e+02 229 1.65e+04 0 6.20e+04 144 3.35e+01 261
REFL_B_RF45_I_PIT 2.78e+05 -16 2.68e+04 169 6.6e+03 -42 1.15e+04 105 1.58e+04 -133 1.36e+02 9 7.3e+02 249 4.24e+04 0.8 9.11e+04 321 8.33e+01 261.1
REFL_B_RF45_Q_PIT 1.19e+05 -16 9.34e+03 158 1.5e+03 172 4.73e+03 -125 5.20e+03 49 4.39e+01 327 4.85e+02 194 2.03e+04 3 9.34e+04 334 3.86e+01 261
POP_X_RF_I_PIT 9.73e+04 166 7.5e+03 90 6.32e+04 161.5 1.04e+04 -87 5.27e+04 108 5.32e+02 186 2.1e+02 341 3.95e+04 179 6.61e+05 319.2 2.98e+00 261
POP_X_RF_Q_PIT 2.75e+03 170 2.01e+04 155 4.8e+02 -51 2.04e+04 -16 1.49e+04 130 1.68e+02 170 4.00e+02 22 4.39e+02 -34 1.04e+04 146 3.5e-02 78
POP_A_PIT 4.76e+00 -18 4.52e-01 -8 2.82e-01 -34 5.8e-02 -47 7.90e-02 -48 9.15e-04 359 8.0e-03 103 3.30e-01 178 5.76e-01 137 1.58e-05 260
POP_B_PIT 1.51e+00 165 1.3e-01 48 1.7e-01 152 1.2e-01 -134 3.68e-02 128 1.95e-03 180 7.6e-03 65 8.68e-01 178 3.76e-01 318 3.42e-05 255
X_TR_A_PIT 3.03e+03 162 2.89e+03 160 8.13e+01 147 6.17e+01 147 2.50e+00 -146 1.41e-01 332 1.11e+00 155 2.37e+00 -179 6.34e+01 321 2.05e-03 272
X_TR_B_PIT 3.68e+03 162 3.40e+03 160 2.43e+02 156 2.16e+02 156 4.34e+00 -157 2.65e-01 338 1.41e+00 164 3.07e+00 -172 7.99e+01 326 2.53e-03 277
Y_TR_A_PIT 3.70e+03 161 3.64e+03 -18 1.39e+02 148 1.44e+02 -33 1.31e+01 123 7.12e-02 349 1.10e+00 312 3.73e+00 158 8.77e+01 305 2.62e-03 262
Y_TR_B_PIT 1.04e+03 162 1.15e+03 -20 6.00e+02 159 6.11e+02 -20 4.67e+00 127 2.19e-01 348 8.3e-01 240 1.34e+00 130 2.66e+01 276 9.00e-04 239

 

We are trying to figure out why the measurements look different compared to 26023  .