This evening during the Operator Handoff, Jeff noticed that the GWI.stat state for H1 (see attached) was in a YELLOW "No good h(t)" state (this was after he had taken it to OBSERVING minutes earlier).
Summary: Only symptom viewable in the Control Room is the GWI.stat. Range looks fine on the BNS FOM on nuc0.
Travis noticed my note about the h(t) issue in my alog and just sent me a text about the issue he had during his graveyard shift & how he fixed it last week (alog35702: EY CRC Error 9:51 UTC).
I do not think this is the issue because we:
Since, there are no alarms/notifications here, will send an email out to the DetChar Group (due to Summary Page), Peter Shawan (due to GWI.stat), & Greg Mendel/Dan Moreu/Dave Barker (due to nagois CRITICAL alarms). Will then wait for any instructions for further action.
The LHO pipelines were restarted at 1177067961. This issue should be fixed in a few minutes when data starts flowing again.
Tagging CAL since it is also related to this issue.