[Greg Mendell, Aaron Viets] Due to the bug found in gstlal-calibration-1.1.5, the DMT machines have been reverted to version 1.1.4. Primary and redundant pipelines, as well as the DMTDQ processes, were restarted at 1177181448. Output looks normal so far.
Aggregation of calibration hoft has been restarted on DCS, with these channels removed,
H1:GDS-CALIB_F_S
H1:GDS-CALIB_F_S_NOGATE
H1:GDS-CALIB_SRC_Q_INVERSE
H1:GDS-CALIB_SRC_Q_INVERSE_NOGATE
starting from 1177181608 == Apr 25 2017 11:53:10 PDT == Apr 25 2017 18:53:10 UTC