Tue Maintenance Summary

Summary of tasks performed Tuesday 24th July for H1 and H2:

h2pemey and h2pemeyaux models were changed to move two ACC channels from pemaux to pemey.

Additional HWS slow channels were added to H2EDCU_HWS.ini

New H2 models for h2susitmy, h2susetmy and h2iscey were installed. We verified that ISC EY is communicating over 4km to the SUS ITMY.

H2 DAQ was restarted due to all the above changes.

rsync of h1boot reduced to daily at 05:20 until the epics slow down problem can be resolved.

a new ethercat ethernet cable was ran from the optics lab to the second ecat port on the h1ecatc0 slow controls computer. Software is being installed to convert the ref cav status to an epics channel.

I completed the h1boot /opt/rtcds/userapps/release area. Each subsystem directory here is now a separate SVN working area. It is no longer possible to svn update the entire userapps working area (which has been done accidentally before).