Reports until 12:29, Monday 01 May 2017
LHO VE
david.barker@LIGO.ORG - posted 12:29, Monday 01 May 2017 - last comment - 13:12, Monday 01 May 2017(35941)
CP3, CP4 manual running of Autofill 2017_05_01

(manual run of the scripts, crontabs were not operational)

Starting CP3 fill. LLCV enabled. LLCV set to manual control. LLCV set to 50% open. Fill completed in 40 seconds. TC B did not register fill. LLCV set back to 18.0% open.

Starting CP4 fill. LLCV enabled. LLCV set to manual control. LLCV set to 70% open. Fill completed in 630 seconds. TC A did not register fill. LLCV set back to 42.0% open.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 12:30, Monday 01 May 2017 (35942)

I've reconfigured the crontab for user vacuum on vacuum1, autofill should run automatically on Wednesday.

chandra.romel@LIGO.ORG - 13:12, Monday 01 May 2017 (35943)

Increased CP4 to 43% open.