Displaying report 1-1 of 1.
Reports until 09:09, Tuesday 02 May 2017
H1 PSL
jason.oberling@LIGO.ORG - posted 09:09, Tuesday 02 May 2017 (35964)
PSL HPO Pump Diode Currents Adjusted (FAMIS 8420)

This morning I adjusted the HPO pump diode currents; this was done with the ISS OFF.  All currents were increase by 0.1 A; a picture of the main screen of the PSL Beckhoff system is attached for future reference.  The table below summarizes the old and new currents:

  Old (A) New (A)
DB1 52.5 52.6
DB2 52.0 52.1
DB3 52.0 52.1
DB4 52.0 52.1

The HPO is now outputting ~169.1 W.  This ISS has been turned back ON.  This completes FAMIS 8420.

Images attached to this report
Displaying report 1-1 of 1.