Reports until 11:11, Wednesday 03 May 2017
H1 AOS (DetChar)
thomas.massinger@LIGO.ORG - posted 11:11, Wednesday 03 May 2017 - last comment - 11:10, Thursday 04 May 2017(35993)
EX/EY oplev laser glitches

TJ Massinger, Derek Davis, Laura Nuttall

Summary: the intervention on April 26th cleaned up the ETMY oplev glitching but the ETMX oplev is still causing problems. Both noise sources have been seen to cause loud background triggers for transient searches when they're glitching.

Since the end station oplev laser glitches have been seen to couple into h(t), we had to develop vetoes based on the BLRMS of the OPLEV_SUM channels to flag and remove these transients from CBC and Burst searches. Using the thresholds that capture the coupling into h(t), we were able to take some long trends of the impact of the oplev glitching using the veto evaluation toolkit (VET).

ETMY results: https://ldas-jobs.ligo-wa.caltech.edu/~tjmassin/detchar/VET/ETMY_OPLEV/1176422418-1177779618/65/

The take home message from this result page is the Omicron glitchgrams. In the first attached image, every blue point is an Omicron trigger. Those in red are triggers coincident with the ETMY L3 OPLEV SUM having a high 10-50 Hz BLRMS. This population of glitches in the bucket was severely damaging for transient searches, but the problem seems to have gone away since the intervention on April 26th (alog 35798). Looking at the segments where the OPLEV SUM BLRMS was high (attachment 2), we see that after April 26th there are few times when the flag is active, which indicates that there are fewer fluctuations in the OPLEV SUM readout.

ETMX results: https://ldas-jobs.ligo-wa.caltech.edu/~tjmassin/detchar/VET/ETMX_OPLEV/1176422418-1177779618/7_5/

Once again, looking at the Omicron glitchgram (attachment 3), every blue point is an Omicron trigger. Those in red are trigger coincident with ETMX L3 OPLEV SUM having a high 45-100 Hz BLRMS (chosen to capture the power fluctuations in the oplev). The ETMX oplev glitches aren't quite as damaging as the ETMY oplev glitches, but they're still producing loud background triggers in the transient searches. Looking at the segments where this flag was active (attachment 4), we see that the ETMX oplev laser has been glitching on and off over the last two weeks and coupling into h(t).

 

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 11:57, Wednesday 03 May 2017 (35994)

I talked to Jason Oberling about this earlier, and it sounds like the same quick fix that worked for ETMY won't work for ETMX, since that laser is already operating near the high end of its power range and I turned up the power on friday (35887). Jason is working on tuning up the one other laser that he has to be ready to make a swap on Tuesday, but the ITMY oplev laser may also be failing so the new laser might be needed for that.  If we need to fix the problem in hardware, the only immediate option we have is to turn off the oplev completely, which will mean that we loose our only independent reference of the optic angle. We're reluctant to loose this especially since we have had several computer crashes recently.  

Is the message of the alog above that the veto is good enough until the laser can be fixed (probably not until the vent)?  

Also, although Jason can probably fix this laser in a few weeks, these lasers fail frequently and we probably will continue to have problems like this throughout the rest of the run.  

 

keita.kawabe@LIGO.ORG - 12:26, Wednesday 03 May 2017 (35997)DetChar

It would be interesting if detchar can also have a look at ITMs and L1.  I'd like to know if similar glitches in oplev power causes similar glitches in DARM regardless of the test mass and IFO, which should be the case if it's radiation pressure.

thomas.massinger@LIGO.ORG - 13:24, Wednesday 03 May 2017 (36000)DetChar

Sheila: The OPLEV SUM channels are good witnesses for this, so we can monitor them and veto glitchy times from the searches. The deadtime from the ETMX glitches isn't much, VET shows 0.04% deadtime over the roughly two weeks I ran this for, so it's not damaging to the search in terms of analysis time if we need to continue to veto them. 

Keita: I'm also curious about the ITMs and L1, they're next up on the list.

thomas.massinger@LIGO.ORG - 11:10, Thursday 04 May 2017 (36023)DetChar

Keita: It looks like the glitches in the ITMs typically have a lower SNR than those in the ETMs. I mentioned this in LLO alog 33531, but will attach the relevant figure here as well.

The attached figure shows SNR histograms of Omicron triggers from the LHO test mass OPLEV_SUM channels with the x-axis restricted to show loud (SNR > 100) triggers. The loudest SNR Omicron triggers in the ITM OPLEV_SUM channels are 450 and 550 for ITMX and ITMY respectively and they're part of a sparse tail of loud triggers. For ETMX and ETMY, the loudest Omicron triggers have SNR 750 and 5500 for ETMX and ETMY respectively and both have a higher population of loud glitches (ETMY in particular).

Images attached to this comment