Reports until 16:57, Friday 05 May 2017
H1 CDS
david.barker@LIGO.ORG - posted 16:57, Friday 05 May 2017 - last comment - 08:08, Saturday 06 May 2017(36057)
scipy version 0.19 is now the default
Comments related to this report
thomas.shaffer@LIGO.ORG - 08:08, Saturday 06 May 2017 (36061)

This seems to be what has been causing some troubles with time machine and a2l. This version of scipy does not have the "special" attribute that these scripts use.