High Voltage Supplies for ESD Drivers

WP 6625
ECR E1600210

The Kepco HV power supplies for ITMX, ITMY, and ETMX were replaced with an equivalent linear supply made by Mid-Eastern Industries Inc. Power supplies for ETMY were replaced on Dec 5 2016. Alog 32186.

New units installed:
S1700114 & S1700115 ITMY/ITMX
S1700116 & S1700117 ETMX
S1610431 & S1610433 ETMY

Comments related to this report
filiberto.clara@LIGO.ORG - 16:21, Tuesday 16 May 2017 (36221)
Units at EY are S1610431 & S1610432. Previous entry with S1610433 is incorrect.