Reports until 17:18, Wednesday 17 May 2017
H1 CDS
thomas.shaffer@LIGO.ORG - posted 17:18, Wednesday 17 May 2017 - last comment - 10:05, Thursday 18 May 2017(36251)
Timing Error

I noticed some red on the CDS Overview and saw that it was a timing error at EY. Verbal reported it at 22:43:43 UTC but was muted for interviews so no one noticed. 

A attached a screenshot of the timing system medms.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 10:05, Thursday 18 May 2017 (36256)

This was due to Robert and Pep's EY investigation on turning off the CNS-II GPS receiver. It was turned back on and the timing error cleared 17:45 PDT