aidan.brooks@LIGO.ORG - posted 13:02, Thursday 18 May 2017 - last comment - 18:10, Thursday 18 May 2017(36254)
HWS alignment summary post May mini-vent and inv-acuum lens replacement

[Aidan,TJ,Nutsinee]

Following the HWSY lens replacement during last week's mini-vent, we have been working to recover the alignment of both HWS beams. Without the ALS beams, this is accomplished using the more laborious method of injecting the HWS beams into the vacuum system, close to centered on the in-vacuum lens, and swinging SR3 around in PITCH and YAW. The return power on the HWS CCDs is plotted as a function of position and yaw. This technique relies on the ITMs being properly aligned.

HWSX

We received no return beam from ITMX in any portion of the PIT and YAW phase space. We concluded that, given the HEPI lock down and ITMX activity last week, ITMX has not returned to the same alignment that it had before the vent. Without access to the ALS beams or the optical levers, it was difficult to make any progress on HWS alignment until the ITMX alignment is corrected. The HWSX alignment effort is on hold until ITMX is fixed.

HWSY

After locating three regions in SR3 angular phase space that held a total of four return beams, we identified which belonged to the ITMY HR surface by running a ring heater test and observing the expected thermal lens (in agreement with the online simulation).

We had to fold the HWSY layout to lengthen the distance from the last lens to the HWSY CCD such that the latter could be placed at the image plane of ITMY. We added an additional optic and moved the HWS CCD as shown in the attached images. The return beam looked much cleaner and the main BS EQ stops look much sharper (less diffraction).

The current status is that the HWSY camera is running WITHOUT the Hartmann plate installed but WITH the bandpass filter installed. The HWSY CCD is currently attached to the HWSX computer (H1HWSMSR) instead of HWSX. This is a temporary measure until the HWSY computer (H1HWSMSR1) is functioning correctly.

Before:

 

After:

HWSY return beam - misaligned to show the EQ stops.

 

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 18:10, Thursday 18 May 2017 (36276)

Since gate valves 1&2 were opened today, we now have optical levers for the ITMs again.  Our alignment restoration that we had been doing earlier this week was restoring to the OSEM values at the L2 stage of the ITMs. 

ITMX was quite far off in both pitch and yaw (it looks like about 15 urad in each from the plot attached, but this is close to the edge of the oplev, so it could be somewhat more than that, but not a lot since the spot responded immediately when I started moving the optic). 

I have now restored the ITMX alignment to much closer to the pre-vent values, so hopefully one of our on-site TCS staff can take a look tomorrow and see if they are now getting a beam back from ITMX.