(CHANNEL, OLV, Offset, Gain)
TOP BOSEMS M1
H1:SUS-PR2_M1_OSEMINF_T1_INMON 29963
H1:SUS-PR2_M1_OSEMINF_T2_INMON 27895
H1:SUS-PR2_M1_OSEMINF_T3_INMON 28003
H1:SUS-PR2_M1_OSEMINF_LF_INMON 28986
H1:SUS-PR2_M1_OSEMINF_RT_INMON 30722
H1:SUS-PR2_M1_OSEMINF_SD_INMON 27004
MIDDLE AOSEMS M2
H1:SUS-PR2_M2_OSEMINF_UL_INMON 25961
H1:SUS-PR2_M2_OSEMINF_LL_INMON 28699
H1:SUS-PR2_M2_OSEMINF_UR_INMON 25278
H1:SUS-PR2_M2_OSEMINF_LR_INMON 25061
LOWER AOSEMS M3
H1:SUS-PR2_M3_OSEMINF_UL_INMON 23599
H1:SUS-PR2_M3_OSEMINF_LL_INMON 24880
H1:SUS-PR2_M3_OSEMINF_UR_INMON 26085
H1:SUS-PR2_M3_OSEMINF_LR_INMON 24842
From the above OLVs, offsets were calculated -(x/2) and gains were calculated 30,000/x, snapshots attached.
Travis set the 6 Tops to 50% OLV in prep for Phase 2a TFs.