Laser Status: SysStat is good Front End Power is 33.98W (should be around 30 W)
HPO Output Power is 165.2W
Front End Watch is GREEN
HPO Watch is GREEN
PMC: It has been locked 5 days, 23 hr 12 minutes (should be days/weeks)
Reflected power = 16.97Watts
Transmitted power = 62.97Watts
PowerSum = 79.94Watts.
FSS: It has been locked for 3 days 18 hr and 40 min (should be days/weeks)
TPD[V] = 2.846V (min 0.9V)
ISS: The diffracted power is around 2.7% (should be 3-5%)
Last saturation event was 5 days 4 hours and 57 minutes ago (should be days/weeks)
Possible Issues: