Determining the best way to respond to 'Unrealistic data for some vacuum channels' problem.

Dave and I had been discussing https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=36294.  One solution we thought about was just disabling the optimization that gave us bad data.  The thinking was that when it was put in we used 1 minute second trend frames.  It would be faster to open one 10 minute second trend frame than ten 1 minute trend frames.  I wanted to characterize the impact of the shared table of contents optimization.

NDS1 variant Timing Notes
Current production code 0.723s Fast, but broken around fw restarts
No TOC optimization 2.077s Slow, but always works.
TOC optimization w/ knowledge of fw restarts 1.595s Medium speed, but always correct.

My thoughts on this are:

1. Getting correct data from nds1 is important, restarting the daq should not be a reason to give bad data (even if it is only for a few minutes).

2. We should preserve the table of contents optimization, it does have some impact.

All timings are from my laptop connecting to the LHO DTS x1nds1 server via an ssh tunnel.  It should be noted there were several restarts of the nds/fw/dc on the DTS during this time window, so the penalty of not being able to share the table of contents is high in these short samples.  I ran the queries below multiple times to make sure the disk cache was hot and picked a representative time for each case.

The measurements:

Quick query against x1nds1 with the current production code (no changes)

$ time nds_query -d 400 -n localhost -p 8088 -s 1179600000 -e 1179603000 X1:DAQ-DC0_DATA_RATE.mean,s-trend
Data for 600 seconds starting at GPS: 1179600000
Channel                                  type      nWords   units
X1:DAQ-DC0_DATA_RATE.mean                real_8       600 
Data for 600 seconds starting at GPS: 1179600600
Channel                                  type      nWords   units
X1:DAQ-DC0_DATA_RATE.mean                real_8       600 
Data for 600 seconds starting at GPS: 1179601200
Channel                                  type      nWords   units
X1:DAQ-DC0_DATA_RATE.mean                real_8       600 
Data for 600 seconds starting at GPS: 1179601800
Channel                                  type      nWords   units
X1:DAQ-DC0_DATA_RATE.mean                real_8       600 
Data for 600 seconds starting at GPS: 1179602400
Channel                                  type      nWords   units
X1:DAQ-DC0_DATA_RATE.mean                real_8       600 

real    0m0.723s
user    0m0.008s
sys    0m0.000s

Quick query against x1nds1 with the frame table of contents optimization disabled.

$ time nds_query -d 400 -n localhost -p 8088 -s 1179600000 -e 1179603000 X1:DAQ-DC0_DATA_RATE.mean,s-trend
Data for 600 seconds starting at GPS: 1179600000
Channel                                  type      nWords   units
X1:DAQ-DC0_DATA_RATE.mean                real_8       600 
Data for 600 seconds starting at GPS: 1179600600
Channel                                  type      nWords   units
X1:DAQ-DC0_DATA_RATE.mean                real_8       600 
Data for 600 seconds starting at GPS: 1179601200
Channel                                  type      nWords   units
X1:DAQ-DC0_DATA_RATE.mean                real_8       600 
Data for 600 seconds starting at GPS: 1179601800
Channel                                  type      nWords   units
X1:DAQ-DC0_DATA_RATE.mean                real_8       600 
Data for 600 seconds starting at GPS: 1179602400
Channel                                  type      nWords   units
X1:DAQ-DC0_DATA_RATE.mean                real_8       600 

real    0m2.077s
user    0m0.000s
sys    0m0.008s

Quick query against x1nds1 with using the table of contents optimization with some additional knowledge of fw restart times.  This is were we need to be, always correct, but able to use some frame access optimizations.  This can be improved by taking into account which restarts are also channel list changes, and which are just restarts.

$ time nds_query -d 400 -n localhost -p 8088 -s 1179600000 -e 1179603000 X1:DAQ-DC0_DATA_RATE.mean,s-trend
Data for 600 seconds starting at GPS: 1179600000
Channel                                  type      nWords   units
X1:DAQ-DC0_DATA_RATE.mean                real_8       600 
Data for 600 seconds starting at GPS: 1179600600
Channel                                  type      nWords   units
X1:DAQ-DC0_DATA_RATE.mean                real_8       600 
Data for 600 seconds starting at GPS: 1179601200
Channel                                  type      nWords   units
X1:DAQ-DC0_DATA_RATE.mean                real_8       600 
Data for 600 seconds starting at GPS: 1179601800
Channel                                  type      nWords   units
X1:DAQ-DC0_DATA_RATE.mean                real_8       600 
Data for 600 seconds starting at GPS: 1179602400
Channel                                  type      nWords   units
X1:DAQ-DC0_DATA_RATE.mean                real_8       600 

real    0m1.595s
user    0m0.004s
sys    0m0.004s