Assembly/In-vacuum cabling - Hugh, Jim, Greg, Hugo
ready
-
Actuators and sensors connected in vacuum
-
In-field cables connected to the feedthroughs
-
ADE boxes of the CPSs grounded
-
Rough balancing performed
-
Locked/Unlocked shift checked (about 0.8v, worse case, on horizontal CPSs)
-
Cables (SEI, ISC) dressed to avoid rubbing while taking transfer Functions
Electronics/MEDM/Models - Dave, Filiberto, Hugo
Model installed and running. Matrices loaded. Sensor readouts available. Can not drive the ISI yet
-
Sensors and actuators were inverted on the input of the Anti-Alias chassis - corrected
-
ADC/DAC organization in the IO chassis was unclear - clarified by testing
-
IOP model issues causing a wrong routing of the ADC/DAC signals - corrected
-
HAM3-ISI model installed
-
HAM3-ISI model updated:
-
ADC to Master model connections modified to match with the in-field cabling.
-
Unused DAC block removed.
-
Watchdogs are tripped due to the Coil Driver Chassis BIO. Impossible to reset the watchdogs, and then actuate on the ISI.
-
Coildrivers are ON.
-
Overheat lights are off.
-
The overheat alarm reset-button was pushed.
-
Coil drivers are connected to the BIO chassis.
-
All testing scripts, but the ones that involve driving were successfully tested
-
Matriced loaded in MEDM.