V. Adya, S. Dwyer, K. Izumi, J. Kissel, P. Thomas After doing the same kind of alignment reference adjustment to the POP QPDs -- i.e. moving around PR2, we were able to surpass yesterday's problems and get through the CARM reduction and closing the ARM's SOFT loops. As such, while holding just before the transition to DC READOUT, we captured new green alignment offsets (updating green QPD offsets and green camera offsets). I attach the relevant screenshots showing the deference between the previous values and the old values. Y arm QPD B Yaw moved the most. The changes to the green camera offsets where in the same direction and rought the same value to which Sheila and I adjusted the offset manually last night. We lost lock due to a dP/dTheta 0.45 Hz oscillation, and are re-running initial alignment, and trying again.