Reports until 14:39, Tuesday 30 May 2017
H1 CDS (VE)
david.barker@LIGO.ORG - posted 14:39, Tuesday 30 May 2017 - last comment - 15:31, Tuesday 30 May 2017(36526)
cell phone alarms, beam tube pressure alarm levels lowered

WP7008

Chandra, Dave:

The high alarm level for beam tube vacuum was lowered from 5.0e-08 to 5.0e-09 Torr for all beam tube gauges except for LX and LY, which are kept temporarily high following the corner station vent. Chandra will open a service-request FRS to request these alarm levels remain high until such time they can be reduced. The FRS will act as a reminder that LX and LY are out-of-configuration.

On Chandra's request I also added CP3's pump LN2 level back into the daily status texts to support ongoing CP3 work (example report shown below).

cp1=92.0  cp2=92.2  cp3=5.6  cp4=0.0  
cp5=92.0  cp6=92.0  cp7=92.0  cp8=92.0  

Comments related to this report
chandra.romel@LIGO.ORG - 15:31, Tuesday 30 May 2017 (36531)