Reports until 12:10, Thursday 01 June 2017
LHO VE
logbook/robot/script0.cds.ligo-wa.caltech.edu@LIGO.ORG - posted 12:10, Thursday 01 June 2017 - last comment - 12:28, Thursday 01 June 2017(36590)
CP3, CP4 Autofill 2017_06_01
CP3 log file DOES NOT exist!
Starting CP4 fill. LLCV enabled. LLCV set to manual control. LLCV set to 70% open. Fill completed in 867 seconds. LLCV set back to 39.0% open.
Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 12:15, Thursday 01 June 2017 (36591)

see  alog36588 for explanation

gerardo.moreno@LIGO.ORG - 12:28, Thursday 01 June 2017 (36592)

Per Chandra,

Increased CP4's LLCV %open value to 40%, up from 39% due to the amount of time it took to fill.