Displaying report 1-1 of 1.
Reports until 11:08, Friday 02 June 2017
H1 CDS (ISC)
david.barker@LIGO.ORG - posted 11:08, Friday 02 June 2017 (36615)
Power cycle of h1iscey

Richard, Dave:

We power cycled the h1iscey computer and IO Chassis as part of the ALS-EY glitch investigation. Sequence was:

h1iscey, stop all models, take FE out of Dolphin fabric, power down comuter

IO Chassis: power cycle

h1iscey, power on computer, models restarted automatically

We had a brief (5 minute) IRIG-B excursion on h1iopiscey. After this cleared, DAQ and IPC were working correctly.

2017_06_02 10:17 h1caley
2017_06_02 10:17 h1iopiscey
2017_06_02 10:17 h1iscey
2017_06_02 10:17 h1pemey
2017_06_02 10:18 h1caley
2017_06_02 10:18 h1iopiscey
2017_06_02 10:18 h1iscey
2017_06_02 10:18 h1pemey
2017_06_02 10:19 h1alsey

 

Displaying report 1-1 of 1.