Reports until 11:17, Monday 05 June 2017
H1 PSL
jim.warner@LIGO.ORG - posted 11:17, Monday 05 June 2017 (36657)
PSL Weekly- FAMIS 7441

Laser Status:
SysStat is good
Front End Power is 34.06W (should be around 30 W)
HPO Output Power is 158.5W
Front End Watch is GREEN
HPO Watch is GREEN

PMC:
It has been locked 3 days, 19 hr 9 minutes (should be days/weeks)
Reflected power = 16.11Watts
Transmitted power = 59.46Watts
PowerSum = 75.57Watts.

FSS:
It has been locked for 0 days 0 hr and 45 min (should be days/weeks)
TPD[V] = 3.415V (min 0.9V)

ISS:
The diffracted power is around 3.2% (should be 3-5%)
Last saturation event was 3 days 19 hours and 9 minutes ago (should be days/weeks)

Possible Issues:
Head 1-4 flow error, see SYSSTAT.adl