PCAL X Temperature Sensor Intermittently Noisy?
J. Kissel

Since we've put the End-Station VEAs on the wall, we noticed that today at 14:12 UTC (Jun 05 2017 07:12:00 PDT) the noise in the XVEA temperature sensor we've posted (H1:CAL-PCALX_RECEIVERMODULETEMPERATURE) dropped by a factor of two. Then, at 23:45 (Jun 05 2017 16:45 PDT) the higher noise state returned. Today's OPS Report suggests that no one went to any end station. More detailed trending shows that this decrease in "temperature" noise did *not* show up in any other VEA temperature sensor. 

Given the rash of what appears to be faulty Beckhoff ADCs (see FRS Tickets 6024, 8250), I wonder if there may be a problem here...

In other news, the very peaky, higher amplitude diurnal temperature oscillations are back.

I'll talk with Bubba tomorrow.
Images attached to this report
Comments related to this report
jeffrey.kissel@LIGO.ORG - 14:01, Thursday 28 June 2018 (42694)CDS
Confirmed still noisy on June 26 2018 (as suspected, no one was informed of the problem beyond this aLOG.)

Opened FRS Ticket 10987.