Reports until 11:43, Thursday 08 June 2017
H1 General
keita.kawabe@LIGO.ORG - posted 11:43, Thursday 08 June 2017 (36732)
SDF before going into observing

ACCEPTed changes:

H1:SUS-ITMY_R0_OPTICALIGN_P_OFFSET (from -150 to -400), this is for HWS and ghost beam (alog 36264).

H1:LSC-PD_DOF_MTRX_SETTING_4_1 and 4_7 (from [0.0091, -849] to [0.035, 0]). These are for PRC input matrix (alog 36473).

H1:ALS-C_COMM_A_DEMOD_LONOM (from  19 to 12). Don't know why it was 19dBm, 12dBm sounds good to me.

H1:ALS-X_LASER_HEAD_NOISEEATERTOLERANCE (from 0.5 to 0.6), H1:ALS-X_REFL_SERVO_COMOFS (from 0.375 to 0.25). These were all changed during the X end investigation.

H1:ALS-Y_REFL_A_DEMOD_LONOM (from 20 to -100) and B_DEMOD_LONOM (from -100 to -9), we used to use channel A but at some point A was broken and we switched to B. Since then the board was swapped and both work but we still use channel B.

H1:ALS-Y_VCO_REFERENCENOM (from 21 to 20).

H1:ALS-X_QPD_A_YAW_OFFSET, H1:ASC-X_TR_A_PIT_OFFSET, H1:ALS-Y_QPD_A_PIT_OFFSET, H1:ALS-Y_QPD_A_YAW_OFFSET, H1:ASC-Y_TR_B_PIT_OFFSET and H1:ASC-Y_TR_B_YAW_OFFSET,  no real change, just the numerical error on the order of 1E-17.

REVERTed changes:

H1:ASL-X_FIBR_LOCK_TEMPERATURECONTROLS_HIGH and LOW were temporarily set to  +-1300 during the X end investigation, doesn't look like we need to keep it, reverted them back to +-600.

H1:ALS-Y_REFL_SERVO_IN2GAIN was set to 1, don't know why but inconsequential, reverted to 0.