Reports until 01:05, Tuesday 13 June 2017
H1 General (DetChar)
patrick.thomas@LIGO.ORG - posted 01:05, Tuesday 13 June 2017 - last comment - 10:02, Tuesday 13 June 2017(36819)
DARM noise
Range is dropping with it. See attached.
Images attached to this report
Comments related to this report
patrick.thomas@LIGO.ORG - 01:08, Tuesday 13 June 2017 (36820)
I have seen this before: alog 35173. If I recall, Jeff K. knew what it was, but I don't remember what he said.
patrick.thomas@LIGO.ORG - 01:15, Tuesday 13 June 2017 (36821)
Found it: alog 35184
sheila.dwyer@LIGO.ORG - 09:07, Tuesday 13 June 2017 (36835)

What is rung up at 6kHz?  That might be the problem.

patrick.thomas@LIGO.ORG - 09:58, Tuesday 13 June 2017 (36839)
Good question. Somehow I hadn't noticed that.

It is not there in the screenshot in the first alog I linked to (from when this happened before).
patrick.thomas@LIGO.ORG - 10:02, Tuesday 13 June 2017 (36840)
Well, maybe it is, but at a much reduced amplitude.