Lock loss at 7:06 UTC. tconvert on GPS time for Seismon gives Jun 14 2017 06:38:54 UTC for time of earthquake and Jun 14 2017 07:15:03 UTC for arrival of R-20 Wave. Seismon and USGS/Terramon do not exactly agree.
Verbal alarms just announced an incoming earthquake at 07:32 UTC. Seismon has updated to the attached screenshot. 07:38 UTC USGS has reported it 07:39 UTC Spike seen on BLRMS
07:45 UTC Watchdogs starting to trip
The following watchdogs tripped:
ISI ETMX stage 2
ISI ITMY stage 2
ISI ITMY stage 1
ISI ETMX stage 1
SUS TMSX
ISI ETMY stage 1
ISI ETMY stage 2