MSR Timing Errors

Jim just called me reporting corner station timing errors. I ran remote MEDMs and saw that the MSR comparator was showing a continuous out-of-nominal error for the fourth channel (Symmetricom GPS) and the Timing Master was intermittently reporting "GPS Not Locked" errors. As I was watching, the comparator channel became nominal, but the master became stuck in the not-locked state. Several minutes later the master corrected itself and the timing system has been continuously GREEN since. There was an alog early in the week about a transient timing error, I'm investigating if this is a re-occurence of the same error.

The front ends did not see any timing issues, the master's oven controlled crystal oscillator (OCXO) remained locked at all times.

Master's MEDM at time of locking error is attached.

Images attached to this report