DB and CG.
killed g1hamisi and g1x01, then rebooted the frontend computer
to clean up its memory [boot performed at 13:50]
DAQD would not run because it needed awgtpman present, so changed daqdrc
to allow running with no awgtpman (otherwise just kept spawning).
Started g1x01 and g1isiham, burt restores worked ok.
Mem usage at this time is (free -m):
[controls@seiteststand ~]$ free -m
total used free shared buffers cached
Mem: 7986 2406 5579 0 82 1062
-/+ buffers/cache: 1262 6724
Swap: 1983 0 1983
Also copied the epics bin area from CDS to the /opt/apps/epics binary directory, but
StripTool does not work.