Displaying report 1-1 of 1.
Reports until 18:21, Tuesday 20 June 2017
H1 ISC
sheila.dwyer@LIGO.ORG - posted 18:21, Tuesday 20 June 2017 - last comment - 20:05, Tuesday 20 June 2017(37046)
Last night's pitch instability

Last night Jeff and Corey had difficulties with large pitch motion of the test masses.  

This is described in a couple of alogs from Corey, and can easily be seen on the summary pages

Suggestion for the operators if you have this problem again:

1) If you see noise in the ITMY oplev laser sum again, try moving CPY around to see if you can get rid of it.  (The ITMY laser is off for now, but you might still see noise on the SUM).

2)If you see that the circulating power is fluctuating at 0.4 Hz, try turning on the PSL 3rd loop. 

 

 

Images attached to this report
Comments related to this report
sheila.dwyer@LIGO.ORG - 20:05, Tuesday 20 June 2017 (37052)

The fringes seen on ITMY must be due to fringes of the OpLev laser with an OpLev ghost beam coming off CPY.  

In the first attached screenshot I am driving CPY in L with 600 counts at 0.1 Hz in R0 DAMP L.  You can see that the fringing got worse then better as I moved CPY to improve the camera image (36936), then I moved the CP to maximize the fringes.  I went to the floor and unplugged the OpLev fiber, and the fringing went away, so this is not from IFO beams. 

Images attached to this comment