Displaying report 1-1 of 1.
Reports until 17:54, Monday 26 June 2017
H1 ISC
sheila.dwyer@LIGO.ORG - posted 17:54, Monday 26 June 2017 (37150)
New SRCL FF

I made a new SRCL FF filter, described in CSWG log 11217

While LLO was down briefly we had the chance to try it out and it seems like the performance is about 10dB better than the old feedforward in the band where we needed improvement, 20-50Hz.  This is now on, in the guardian and accepted in SDF. 

It seems to have reduced the srcl coherence, and perhaps had a tiny positive impact on the DARM noise. (3rd attachment)

Images attached to this report
Displaying report 1-1 of 1.