Reports until 15:56, Tuesday 27 June 2017
H1 AOS
david.barker@LIGO.ORG - posted 15:56, Tuesday 27 June 2017 - last comment - 16:32, Tuesday 27 June 2017(37174)
Charge measurement scripts are working

FRS8218

Jeff, Dave:

This morning during maintenance Jeff successfully ran the charge measurement script on ETMX and ETMY. I'll let him fill in the details, but this closes the LHO part of FRS8218. We suspect the core problem was an nds2 which has since been resolved.

The "red herring" SIStrLog error turned out to be a true error, fixed by opening up file permissions in the /ligo/logs/h1/inject_log area. I've opened FRS8405  to cover this.

 

Comments related to this report
david.barker@LIGO.ORG - 16:32, Tuesday 27 June 2017 (37177)

I'm not sure this is common knowledge, but every time an awgstream runs it logs in a daily log file, for example

/ligo/logs/h1/injection_log/2017/06/27/injection.txt

...

1182627394.000000 H1:SUS-ETMY_L3_ESDOUTF_LL_EXC start zotws10 16523 1 awgstream ./test_sinewave_ETMY.txt 1
1182627418.059011 H1:SUS-ETMY_L3_ESDOUTF_LL_EXC stop  zotws10 16523 1
1182627430.000000 H1:SUS-ETMY_L3_ESDOUTF_UR_EXC start zotws10 16536 1 awgstream ./test_sinewave_ETMY.txt 1
1182627454.055341 H1:SUS-ETMY_L3_ESDOUTF_UR_EXC stop  zotws10 16536 1
1182627466.000000 H1:SUS-ETMY_L3_ESDOUTF_LR_EXC start zotws10 16548 1 awgstream ./test_sinewave_ETMY.txt 1
1182627490.054266 H1:SUS-ETMY_L3_ESDOUTF_LR_EXC stop  zotws10 16548 1