Reports until 15:56, Friday 30 June 2017
H1 SEI (SEI)
Link
cheryl.vorvick@LIGO.ORG -
posted 15:56, Friday 30 June 2017
(37254)
Incoming Earthquake: 6.1
22:34:07UTC - Verbal Alarm
22:35UTC - started the switch to Earth_Quake_2
22:37:20UTC - transition complete, GEOfon and EMSC reporting the EQ
22:42UTC - P-wave arrives Terramon and USGS not yet reporting
22:50 - USGS reported
as of 22:51UTC - H1 is still locked, range droped to about 40Mpc and is currently back at 63Mpc
22:54UTC - Terramon reported
0.03-0.1Hz spiked to about 0.6um/s
0.1-0.3Hz spiked to about 0.4um/s