Displaying report 1-1 of 1.
Reports until 19:45, Monday 03 July 2017
H1 ISC (ISC, SUS)
cheryl.vorvick@LIGO.ORG - posted 19:45, Monday 03 July 2017 - last comment - 00:57, Tuesday 04 July 2017(37300)
Corrected H1 glitching with alignment of TMSX and TMSY

First attachment:

Second attachment:

Total time out of Observe = 54 minutes.

Images attached to this report
Comments related to this report
patrick.thomas@LIGO.ORG - 20:51, Monday 03 July 2017 (37303)
Nice!
cheryl.vorvick@LIGO.ORG - 23:40, Monday 03 July 2017 (37305)
  • TMSX and TMSY went more than 3 days and 4 locks with the same alignment.
  • I believe this alignment was good enough to lock, but the arms as defined by the ITM and ETM moved, and possibly TMS drifted as well, and then TMS was no longer optimally aligned to the arm.
  • Since going back to Observe, there has been at least one EQ that degraded the range, other large glitches have been in the bucket, and I'm not sure from what, but the glitches before aligning TMSX/Y were lower frequency.
Images attached to this comment
cheryl.vorvick@LIGO.ORG - 00:57, Tuesday 04 July 2017 (37308)
Displaying report 1-1 of 1.