Displaying report 1-1 of 1.
Reports until 12:38, Wednesday 05 July 2017
H1 CDS
david.barker@LIGO.ORG - posted 12:38, Wednesday 05 July 2017 - last comment - 13:20, Wednesday 05 July 2017(37331)
restarted all models at EY and on h1sush2b

An earlier glitch required a restart of all models at EY (h1susey, h1seiey, h1iscey and h1susauxey). The order was to stop all models on the Dolphin'ed machines, then start all the models in the order h1iscey, h1seiey and h1susey. Then the sus aux was stop-started. Finally all IPC errors and CRCs were cleared.

Later an unknown glitch caused the models on h1sush2b (sus-im system) to stop. The dmesg is just showing Dolphin-like errors. I stopped and restarted the two models on this system.

Comments related to this report
jeffrey.kissel@LIGO.ORG - 13:20, Wednesday 05 July 2017 (37332)CDS, SUS
I've opened two FRS Tickets (and marked as pending for closure) for the record on these front-end crashes:
EY Computers: 8452
h1susham2b: 8451