Peter and Jason have brought the PSL back. I have run an initial alignment. I just got stopped in VIOLIN_MODE_DAMPING_1 by an ezca connection error to H1:SUS-ITMX_L2_DAMP_MODE7_SW2R (see attached). I tried reloading the code but the error persists. I can connect to the channel with caget from zotws3 (as myself) and from h1guardian1 (as controls).
It seems that I have managed to fix it by following the suggestion in the log and taking ISC_LOCK to STOP and then EXEC. It seemed to get stuck at PAUSE so I re-requested EXEC and it then went to EXEC. I then requested DC_READOUT and it made it to that. I noticed the attached 'invalid value encountered in divide' error go by.