Reports until 11:57, Thursday 13 July 2017
H1 SEI (OpsInfo)
jim.warner@LIGO.ORG - posted 11:57, Thursday 13 July 2017 (37497)
Seismon epics code & screen updated for 5 earthquake display

LLO has had this for a while, but with help from DaveB, Arnaud, KeithT, SebB and MichaelC, we now how a seismon screen that shows the last five earthquakes. With the old single event screen it was conceivable that a smaller earthquake could happen after a larger, problematic earthquake arrived, making it difficult to identify the source in the case of a eq induced lockloss. There are still a number of issues with the new code (some inconsistencies in channel names, new channel names not in the DAQ, the Location name doesn't display on the new overview, some of the old code is still running to keep EDCUs happy...), but at the moment it mostly seems to work. This probably will break the verbal notifications until TJ and I have a chance to talk about how to update the test.

I'm also not sure how stable the new configuration is, so I'd like to ask operators to keep the an eye on the screen and let me know if seismon's list continues to agree with the USGS list. Unfortunately, this change also breaks the old seismon screen, though I'll leave the link on the sitemap up, is case we go back to the old code. The new screen can be found by going to SEI --> SEISMON-5_event on the sitemap.

Images attached to this report