WP 7075
To further proceed with the 72 MHz WFS (Wave Front Sensor)s (37042), today I made the hardware changes (mostly cabling), as summarized below, while the interferometer was in a violin-mode-damping state.
I am going to leave the hardware configuration as it is. If this new setup doesn't cause extra noise in the interferometer, they will stay semi-permanently.
Here is a summary of the new configuration:
[The modifications]
Later, Jenne pointed out that the dark offset should have been readjusted. So we re-adjusted the dark offset. As a result, the -1 dB gain I originally placed turned out to be inaccurate. I set it to 2 dB in order to get roughly 550 counts at the normalized in-phase output when the DRMI is locked with the arm at a off resonance point. The RF phase is also adjusted accordingly.
It seems like since this work there has been excess low frequency noise in the RF9 AM stabilization control signal. The attachment shows the difference.