Reports until 06:06, Friday 14 July 2017
H1 General (SEI)
travis.sadecki@LIGO.ORG - posted 06:06, Friday 14 July 2017 - last comment - 07:34, Friday 14 July 2017(37514)
Lockloss 12:58 UTC - Earthquake ?

I set the OPS_OBSERVATORY-MODE to Earthquake, but I'm not entirely certain that was the culprit.  We were at the peak of the motion from a 5.3M EQ in Chile, but the BLRMS top out at only ~0.1 um/s, so well below the typical lockloss threshold.  Jim's StripTool shows some wiggles in the BS CPS traces, but not what I'd call glitches.

For the SEI team, I attach screenshots of the USGS, Terramon, and SEISMON 5-EQ screens that show that SEISMON is not reporting the latest EQs (there have been several EQs over 4.0M with dates of 2017-07-14 that don't show up on SEISMON). 

Images attached to this report
Comments related to this report
keith.thorne@LIGO.ORG - 07:34, Friday 14 July 2017 (37516)CDS, SEI
SEISMON seems to be working (at least updating) at LLO (See attached).

We made need to update the USGS code, and other code to get the location field to work.  There is also the phenomenon that after a restart of all the scripts it can take a couple days for all the processing to catch up to current events.
Images attached to this comment